Copper Tube Computer Cooling Water Cooler Plate

Metalli's liquid cooling plate technologies include vacuum or controlled atomsphere brazed cold plate, Friction Stir Welded (FSW) performance-fin cold plates, flat tube cold plates, press copper tubed cold plates, copper cold plates.

Metalli's cooling paltes are widely used in power electronics, ev battery, data center, medical equipment, lasers and wind turbines.

All prodcuts can be customized as your requirements. Support OEM/ODM. 100% meets the standards of GB, SGS, CE.
Availability:

Product name : Battery Cooling Liquid Heat Exchanger Cold Plate Copper Tube Computer Cooling water cooler plate


                                                 PRODUCT DESCRIPTION

NO.

ITEM

DESCRIPTION

1

Material for base

Aluminum alloy 3003, 6063,6061

2

Material for tube

T2 pure copper

3

Tube Size

Φ9.52*0.7,10*1,10*1.5,12*1,12*1.5,12.7*0.7,14*1,16*1   mm

4

Dimension (L*W*T)

600*500*15 mm

5

Cooling Capacity

1 KW

6

Working Pressure

3 to 4 bars

7

Flatness

0.15 mm

6

Surface roughness

3.2 um

7

Flow rate

6 to 10 L/min

8

Manufacturing Method

CNC machining, rolling tube, pressing and glue   sealing

9

Joining Method

Press lock and glue sealing

10

Cooling Method

Liquid cooling

11

Surface Finish

Mill finish or anodization

12

Coolant

Deionized Water,Inhibited Glycol and Water,Dielectric   fluid

13

Warranty time

1 year

14

Place of Region

Jiangsu province of China

15

Reference Standard

GB/T 3190-2008,GB/T 14846-2008,ISO 2768


Metalli’s cold plate technologies include


◆ Vacuum brazed or controlled atmosphere brazed and CNC machined performance fin cold plates and chassis

◆ Friction Stir Welded (FSW) performance-fin cold plates and chassis

◆ flat tube cold plates

◆ Press lock Copper tubed cold plates

◆ Vacuum brazed and CNC machined copper cold plates

◆ Stamped and vacuum brazed cold plates

◆ Gun-drilled custom cold plate

◆ Custom channeled cold plate with ladder configuration

◆ Inner-Finned Brazed Cold Plates

◆ Aluminum extruded and welded or brazed cold plate

◆ Aluminum die casting and welded or brazed cold plate

Copper Cpu Water Cooling Block liquid cooling system

▲ Components for vacuum brazed cold plate

Aluminum Cooling Block Vacuum Aluminum Brazing battery cooling plate

▲ Stamped and vacuum brazed cold plate

Aluminium and copper liquid water block cold plate cooler with copper tube 11013-4

▲ Copper tubed cold plate


We also supply value added components as below

●    Fittings and connectors

●    Hoses and tubes

●    Heat exchangers or radiators

●    Pumps and reservoirs

●    Fans

●    Other accessories

Radiator

                                  ▲ Radiator                                                                          ▲ Pump



Brief of a liquid cooling system


There are many ways to accomplish liquid cooling, but the most common method is to have a plate with a flow path that moves liquid under the devices. After the heat is absorbed into the liquid, it is taken out of the plate and into the larger system. While water or water/glycol are the most common fluids used in liquid cooling, gasoline, oil, and refrigerant are other fluids that can be utilized.

There are lots of ways to construct a cold plate and the methods can be driven by the level of performance needed, the materials needed or the environmental requirements.

One construction method is to use a series of cross-drilled holes in a plate. The holes intersect in the plate to determine the flow pattern and unneeded patterns are plugged. This construction method can be cost effective, but the pattern is limited to straight lines.

Another method is to embed a tube in a plate by machining a groove in the plate. The tube can either be placed toward the top surface of the plate to provide better cooling to devices mounted on that surface, or it can be embedded further into the plate so that it cools devices mounted on both sides of the plate. This option provides greater flexibility, but the thermal performance is limited because of the surface area of the tube perimeter.

To get more performance, extended surface area in contact with the fluid is required and this leads to machined cold plates. The cold plate is constructed of a plate that has been machined to form some flow passages and then a cover is assembled to capture the flow. The extended surface area can be machined in place or installed by use of a piece of folded fin. The cover can be flat or be another machined plate. The method of assembly of the two parts can be done by gasket/screw, glue/screw, brazing, or welding and is dependent on the required performance and the requirements of the environment.


Previous: 
Next: 
Contact Us
NANJING METALLI INDUSTRIAL CO., LIMITED

Contact Us

    NO. 12 East mozhou road, Jiangning development zone, Nanjing, China
    Tel : +8625-86136265
    Fax :  +8625-86136302
// :  +86-136-2610-7044
    E-mail : info@njmetalli.com
    Skype : fly20091116

Zip Code: 211111
Copyright  2023 NANJING METALLI INDUSTRIAL CO., LIMITED                                         苏ICP备2022030411号-1